Mold Envelope vs. Tie-Bar Opening Screen
Check whether a mold envelope fits a press tie-bar opening as entered or after a 90-degree rotation.
Example starting values are prefilled to demonstrate the calculation. Replace them with your measured, quoted, or job-specific inputs before relying on a result.
Result
Fits tie-bar opening in at least one orientation
Fits
Does not fit
Entered orientation height clearance (in)
2.000
Entered orientation width clearance (in)
1.000
Rotated orientation height clearance (in)
4.000
Rotated orientation width clearance (in)
-1.000
Geometric screen limitation
A positive clearance means geometric space remains in that orientation; zero means exact nominal boundary; negative means interference. If either orientation fits, the mold passes only this rectangular tie-bar-opening screen. Confirm the OEM machine drawing and separately check mold height, platen/clamp geometry, locating ring, daylight, stroke, lifting path, and loads.
Related calculators
Clamp Force / Tonnage Screening Estimate
Screen press tonnage from projected mold area, cavity pressure, and the engineering margin you choose.
Open calculatorInjection Unit Shot Utilization and Capacity Check
Compare a molded shot with the injection unit rating to see how much shot capacity remains.
Open calculatorThermoplastic Mold Cavity Size from Measured Shrinkage
Convert a target molded dimension and measured shrinkage into a starting cavity dimension for mold layout.
Open calculatorDimensional Process Capability (Cp / Cpk)
Use drawing limits, process mean, and within-subgroup variation to review Cp, Cpk, and dimensional margin.
Open calculator